ESTABLISHMENT OF REGIONAL DIAGNOSTIC REFERENCE LEVELS IN ADULT COMPUTED TOMOGRAPHY FOR FOUR AFRICAN COUNTRIES: A
Vera Uushona1, Mary Boadu2, Rose Nyabanda3
1National Radiation Protection Authority of Namibia, Ministry of Health and Social Services, Windhoek, Namibia.
Abstract:
This preliminary study aims towards the establishment of regional diagnostic reference levels (DRLs) for routine adult computed tomography (CT) examinations. The study was performed on 54 CT facilities from four African countries (Ghana, Kenya, Namibia and Senegal) and the results compared with international DRLs. Data were collected from facilities using a structured questionnaire provided by the International Atomic Energy Agency. Dose descriptors (volume computed tomography dose index [CTDIvol] and dose length product [DLP]) evaluations were performed on CT head and body phantoms for head, chest and abdomen CT examination protocols using standard methods. The estimated dose indices were compared with console-displayed dose values. Experienced radiologists accepted the diagnostic image quality of the images as per departmental imaging requirements. Median CTDIvol and DLP data from each facility were compiled to estimate the typical dose in each country. National DRLs were established based on the 75th percentile of median values, whereas the regional DRLs were based on the median of the national DRLs. Comparison of measured CTDIvol with console values of all facilities in all four countries was within 20% as recommended. The established CTDIvol DRLs for head CT, chest CT and abdomen CT were 60.9 mGy, 15.2 mGy and 15.7 mGy, respectively. Similarly, that of DLP, DRLs were 1259 mGy.cm, 544 mGy.cm and 737 mGy.cm, respectively for head CT, chest CT and abdomen CT. The established DRLs from this study were comparable to DRLs from other countries with some variations. This study would serve as baseline for establishment of a more generalized regional adult CT DRLs for Africa.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT