Related Experiment Video
Updated: Sep 22, 2025

Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
The Effect of Endotracheal Suctioning Using the Four-handed Care on Physiological Criteria and Behavioral Responses
Somayeh Sadeghi Niaraki1, Batool Pouraboli1, Aida Safaiee Fakhr2
1Department of Pediatric and Neonatal Nursing, School of Nursing and Midwifery, Tehran University of Medical Sciences, Tehran, Iran.
Background: Endotracheal suctioning, despite its necessity, is one of the procedures that can cause pain and stress for infants admitted to neonatal intensive care units. Pain and stress manifest with physiological and behavioral responses in infants. Purpose: This study is a cross-sectional clinical trial that aimed to investigate the effect of endotracheal suctioning using four-handed care on the physiological criteria and behavioral responses of preterm infants. Methods:In this study, 40 infants were randomly divided into two groups of 20, one group was first suctioned by the routine method (two hands) and then with the four-handed method. The other group was first suctioned by the four-handed method and then with the routine one. The ALPS NEO was used to evaluate behavioral criteria. One camera recorded facial expressions and body movements, and physiological data were recorded from the monitor simultaneously. Results:Four-handed suctioning method can prevent an increase in heart rate during and two minutes after suctioning but it did not affect behavioral responses and oxygen saturation of the preterm infants admitted to NICUs. Since one of the symptoms of pain and stress in infants is the change of vital signs, especially the heart rate, stable heart rate during painful procedures can be an indication of the effectiveness of the four-hand method in invasive procedures such as suctioning. Implications for Practice: We recommend four-handed method for suctioning of endotracheal tube. Implications for Research: Evaluate the effect of four-handed care by mother on physiological criteria and behavioral responses of the preterm infants.
Background: Endotracheal suctioning, despite its necessity, is one of the procedures that can cause pain and stress for infants admitted to neonatal intensive care units. Pain and stress manifest with physiological and behavioral responses in infants. Purpose: This study is a cross-sectional clinical trial that aimed to investigate the effect of endotracheal suctioning using four-handed care on the physiological criteria and behavioral responses of preterm infants. Methods:In this study, 40 infants were randomly divided into two groups of 20, one group was first suctioned by the routine method (two hands) and then with the four-handed method. The other group was first suctioned by the four-handed method and then with the routine one. The ALPS NEO was used to evaluate behavioral criteria. One camera recorded facial expressions and body movements, and physiological data were recorded from the monitor simultaneously. Results:Four-handed suctioning method can prevent an increase in heart rate during and two minutes after suctioning but it did not affect behavioral responses and oxygen saturation of the preterm infants admitted to NICUs. Since one of the symptoms of pain and stress in infants is the change of vital signs, especially the heart rate, stable heart rate during painful procedures can be an indication of the effectiveness of the four-hand method in invasive procedures such as suctioning. Implications for Practice: We recommend four-handed method for suctioning of endotracheal tube. Implications for Research: Evaluate the effect of four-handed care by mother on physiological criteria and behavioral responses of the preterm infants.
More Related Videos
07:11Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
Published on: February 5, 2019
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Related Concept Videos
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....