The solvent strength parameter (slope) and intercept (log kw) of the linear solvent strength model are determined for methanol-water (17 columns), acetonitrile-water (15 columns), acetone-water (7 columns), tetrahydrofuran-water (6 columns), and 2-propanol-water (4 columns) for varied compounds. It is shown that the linear region of the plots of the retention factor (log k) against the volume fraction of organic solvent (ϕ) is largely a system property independent of solute type for compounds with accessible retention factors. Solvent strength parameters for methanol (3.12 ± 0.12), acetonitrile (2.78 ± 0.18), acetone (2.71 ± 0.11), and tetrahydrofuran (2.95 ± 0.24) are assigned for siloxane-bonded silica and porous graphitic carbon columns as an average of the compound-specific experimental values. Statistical analysis indicates that the compound-specific solvent strength parameters are column dependent and limited as a general solvent property. Evaluation of the column-specific solvent strength parameters provides further evidence that the average solvent strength parameter is column dependent. The column-specific solvent strength values are compared with the hypothetical water-organic solvent distribution systems using the system constants of the solvation parameter models as variables confirming the column dependence of the solvent strength parameter. The column-specific solvent strength parameters can be predicted by the solvation parameter model with a typical deviation of about 0.12 over a range of 1.69 to 6.33 for the experimentally determined values. The intercept of the linear solvent strength model is shown to be both column and organic solvent dependent. Compound column-specific values are adequately described by the solvation parameter model. Log kw cannot be recommended as a descriptor of solute properties since it has no clear connection to a real distribution system.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.