Comparison of Assist/Control Ventilation with and without Volume Guarantee in Term or Near-Term Infants
Handan Bezirganoglu1,2, Nilufer Okur1,3, Mehmet Buyuktiryaki1,4
1Division of Neonatology, Department of Pediatrics, University of Health Sciences, Ankara City Hospital, Ankara, Türkiye.
Objectives:
This study aimed to compare the effects of volume guarantee (VG) combined with assist/control (AC) ventilation to AC alone on hypocarbia episodes and extubation success in infants born at or near term.
Methods:
In this prospective cohort study, infants >34 weeks of gestation at birth, who were born in our hospital supported by synchronized, time-cycled, pressure limited, assist/control ventilation (AC) or assist-controlled VG mechanical ventilation (AC + VG) were included. After admission, infants received either AC or VG + AC using by Leoni Plus ventilator. The ventilation mode was left to the clinician. In the AC group, peak airway pressure was set clinically. In the VG + AC group, desired tidal volume was set at 5 mL/kg, with the ventilator adjusting peak inspiratory pressure to deliver this volume. The study was completed once the patient extubated.
Results:
There were 35 patients in each group. Incidence of hypocarbia was lower in the VG + AC compared with AC (%17.1 and 22.8%, respectively) but statistically not significant. Out-of-range partial pressure of carbon dioxide (PCO2) levels were lower in the VG + AC group and it reached borderline statistical significance (p = 0.06). The median extubation time was 70 (42-110) hours in the VG + AC group, 89.5 (48.5-115.5) hours in the AC group, and it did not differ between groups (p = 0.47).
Conclusion:
We found combining AC and VG ventilation compared with AC ventilation alone yielded similar hypocarbia episodes and extubation time for infants of >34 gestational weeks with borderline significance lower out-of-range PCO2 incidence.
Key Points:
· Underlying lung pathology requiring mechanical ventilation support in term infant is heterogeneous.. · VG ventilation compared with conventional modes yielded similar hypocarbia episodes in term infants.. · Combining VG ventilation lead to borderline significance lower out-of-range PCO2 incidence..
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: