Related Experiment Video
Updated: Sep 21, 2025

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Development, Optimization, and Validation of Forensic Analytical Method for Quantification of Anticholinesterase
André Rinaldi Fukushima1,2, Juliana Weckx Peña-Muñoz3, Luís Antônio Baffile Leoni3
1Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, São Paulo 05508-270, Brazil.
Abstract:
Anticholinesterase pesticides are a main cause of the intentional or accidental poisoning of animals. Anticholinesterases include several substances that cause the overstimulation of both central and peripheral acetylcholine-dependent neurotransmission. Forensic analyses of poisoning cases require high levels of expertise, are costly, and often do not provide reliable quantitative information for unambiguous conclusions. The purpose of the present study was to develop and validate a method of high-performance liquid chromatography with diode array detector (HPLC−DAD) for the identification and quantitation of n-methyl carbamates, organophosphates and respective metabolites from biological samples of animals that were suspected of poisoning. HPLC−DAD is reliable, fast, simplistic and cost-effective. The method was validated for biological samples obtained from stomach contents, liver, vitreous humor and blood from four different animal species. The validation of the method was achieved using the following analytical parameters: linearity, precision, accuracy, selectivity, recovery, and matrix effect. The method showed linearity at the range of 25−500 μg/mL, and the correlation coefficient (r2) values were >0.99 for all matrices. Precision and accuracy were determined by the (a) coefficient of variation (CV), (b) relative standard deviation low-quality control (LQC), (c) medium-quality control (QCM), and (d) high-quality control (QCA). The indicated parameters were all less than 15%. The recovery of analytes ranged from 31 to 71%. The analysis of results showed no significant interfering peaks due to common xenobiotics or matrix effects. The abovementioned method was used to positively identify pesticide analytes in 44 of the 51 animal samples that were suspected of poisoning, demonstrating its usefulness as a forensic tool.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:20Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023