Related Experiment Video
Updated: Sep 21, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Evaluation by a Machine Learning System of Two Preparations for Small Bowel Capsule Endoscopy: The BUBS (Burst
Charles Houdeville1,2, Romain Leenhardt1,2, Marc Souchaud2
1Sorbonne University, Center for Digestive Endoscopy, Saint-Antoine Hospital, APHP, 75012 Paris, France.
Abstract:
Background: Bubbles often mask the mucosa during capsule endoscopy (CE). Clinical scores assessing the cleanliness and the amount of bubbles in the small bowel (SB) are poorly reproducible unlike machine learning (ML) solutions. We aimed to measure the amount of bubbles with ML algorithms in SB CE recordings, and compare two polyethylene glycol (PEG)-based preparations, with and without simethicone, in patients with obscure gastro-intestinal bleeding (OGIB). Patients & Methods: All consecutive outpatients with OGIB from a tertiary care center received a PEG-based preparation, without or with simethicone, in two different periods. The primary outcome was a difference in the proportions (%) of frames with abundant bubbles (>10%) along the full-length video sequences between the two periods. SB CE recordings were analyzed by a validated computed algorithm based on a grey-level of co-occurrence matrix (GLCM), to assess the abundance of bubbles in each frame. Results: In total, 105 third generation SB CE recordings were analyzed (48 without simethicone and 57 with simethicone-added preparations). A significant association was shown between the use of a simethicone-added preparation and a lower abundance of bubbles along the SB (p = 0.04). A significantly lower proportion of “abundant in bubbles” frames was observed in the fourth quartile (30.5% vs. 20.6%, p = 0.02). There was no significant impact of the use of simethicone in terms of diagnostic yield, SB transit time and completion rate. Conclusion: An accurate and reproducible computed algorithm demonstrated significant decrease in the abundance of bubbles along SB CE recordings, with a marked effect in the last quartile, in patients for whom simethicone had been added in PEG-based preparations, compared to those without simethicone.
More Related Videos
07:13Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model
Published on: April 18, 2025
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...