Quantification of Lung Perfusion Blood Volume in Dual-Energy Computed Tomography in Patients with Pulmonary
Satoko Ugawa1,2, Satoshi Akagi1, Kentaro Ejiri1
1Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama 700-8558, Japan.
Abstract:
Dual-energy computed tomography (DECT) is a promising technique for the assessment of the lung perfused blood volume (LPBV) in the lung parenchyma. This study was performed to compare the LPBV by DECT of patients with pulmonary hypertension (PH) and controls and to evaluate the association between the LPBV and the perfusion ratio derived by lung perfusion scintigraphy. This study involved 45 patients who underwent DECT (25 patients with PH and 20 controls). We measured the total LPBV and distribution of the LPBV in each lung. The total LPBV was significantly lower in the PH group than the control group (38 ± 9 vs. 45 ± 8 HU, p = 0.024). Significant differences were observed between the LPBV of the upper lung of the PH and control groups (34 ± 10 vs. 47 ± 10, p = 0.021 and 37 ± 10 vs. 47 ± 8, p < 0.001). A significant correlation was observed between the LPBV and the lung perfusion scintigraphy. A lower total LPBV and lower LPBV of the upper lung as detected by DECT might be specific findings of PH.