Related Experiment Video
Updated: Sep 21, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Preclinical Assessment of Nebulized Surfactant Delivered through Neonatal High Flow Nasal Cannula Respiratory Support
Francesca Ricci1, Arianna Mersanne1, Matteo Storti1
1Department of Preclinical Pharmacology, R&D, Chiesi Farmaceutici S.p.A., 15739 Parma, Italy.
Abstract:
High-flow nasal cannula (HFNC) is a non-invasive respiratory support (NRS) modality to treat premature infants with respiratory distress syndrome (RDS). The delivery of nebulized surfactant during NRS would represent a truly non-invasive method of surfactant administration and could reduce NRS failure rates. However, the delivery efficiency of nebulized surfactant during HFNC has not been evaluated in vitro or in animal models of respiratory distress. We, therefore, performed first a benchmark study to compare the surfactant lung dose delivered by commercially available neonatal nasal cannulas (NCs) and HFNC circuits commonly used in neonatal intensive care units. Then, the pulmonary effect of nebulized surfactant delivered via HFNC was investigated in spontaneously breathing rabbits with induced respiratory distress. The benchmark study revealed the surfactant lung dose to be relatively low for both types of NCs tested (Westmed NCs 0.5 ± 0.45%; Fisher & Paykel NCs 1.8 ± 1.9% of a nominal dose of 200 mg/kg of Poractant alfa). The modest lung doses achieved in the benchmark study are compatible with the lack of the effect of nebulized surfactant in vivo (400 mg/kg), where arterial oxygenation and lung mechanics did not improve and were significantly worse than the intratracheal instillation of surfactant. The results from the present study indicate a relatively low lung surfactant dose and negligible effect on pulmonary function in terms of arterial oxygenation and lung mechanics. This negligible effect can, for the greater part, be explained by the high impaction of aerosol particles in the ventilation circuit and upper airways due to the high air flows used during HFNC.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...