Structural Behavior of RC Beams Containing Unreinforced Drilled Openings with and without CFRP Strengthening
Alaa A El-Sisi1,2, Hesham M El-Emam3, Abd El-Monem I El-Kholy3
1Civil and Environmental Engineering, University of Missouri, Columbia, MO 65211, USA.
Abstract:
Construction deficiencies can cause serious problems that significantly decrease the design strength of concrete structures, such as the unreinforced drilled openings. With the absence of sufficient reinforcement, the stress concentrations generated around the opening corners produce cracks in the beams. The size and location of the opening significantly affect the behavior of the beam under static and dynamic load. In this work, an experimental and numerical program was performed to investigate the behavior of drilled reinforced concrete beams with and without strengthening using CFRP sheets. Energy absorption and SDOF analyses were performed to preliminary assess the behavior of the beams under the dynamic load, such as blast. One control beam without any openings, six beams with tension-zone openings, and six beams with shear-zone openings were tested. It was found that the samples with tension-zone openings were slightly affected by the opening, where the reduction in the ultimate strength was approximately 7 to 14%. The beams were able to recover up to 46% of the lost strength by CFRP strengthening. On the other hand, the shear-zone opening significantly decreased the strength and energy absorption and increased the blast response. It can be concluded that it is not recommended to drill any opening at the shear zone as strength loss can reach 57% even with the strengthening, especially for blast resisting structure; in addition, the strength recovered from approximately 11.95 to 32.46% only. The finite element model was able to predict the strength of the beams. The results were closer in the case of tension-zone opening than those in the case of the shear-zone opening. Shear cracks were observed at the corners of the openings even if the opening exists at the tension zone. A reduction in the density of cracks can be observed after the strengthening, where the FRP sheet decreases the stress in the concrete.
Related Concept Videos
Design of Prismatic Beams for Bending
Fiber Reinforced Concrete
Reinforcements in Concrete
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Design Example: Distributing Reinforcements in Concrete Sections
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...