Related Experiment Video
Updated: Sep 21, 2025

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Linear and Non-Linear Soft Sensors for Predicting the Research Octane Number (RON) through Integrated
Tiago Dias1,2, Rodolfo Oliveira2, Pedro M Saraiva1,3
1Department of Chemical Engineering, University of Coimbra, CIEPQPF, Rua Sílvio Lima, Pólo II-Pinhal de Marrocos, 3030-790 Coimbra, Portugal.
Abstract:
The Research Octane Number (RON) is a key quality parameter for gasoline, obtained offline through complex, time-consuming, and expensive standard methods. Measurements are usually only available a few times per week and after long delays, making process control very challenging. Therefore, alternative methods have been proposed to predict RON from readily available data. In this work, we report the development of inferential models for predicting RON from process data collected in a real catalytic reforming process. Data resolution and synchronization were explicitly considered during the modelling stage, where 20 predictive linear and non-linear machine learning models were assessed and compared using a robust Monte Carlo double cross-validation approach. The workflow also handles outliers, missing data, multirate and multiresolution observations, and processes dynamics, among other features. Low RMSE were obtained under testing conditions (close to 0.5), with the best methods belonging to the class of penalized regression methods and partial least squares. The developed models allow for improved management of the operational conditions necessary to achieve the target RON, including a more effective use of the heating utilities, which improves process efficiency while reducing costs and emissions.
Related Concept Videos
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...

