Predictors of extubation outcomes among extremely and very preterm infants: a retrospective cohort study
1Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Neonatal Intensive Care Unit, Guangzhou, China.
Objective:
To explore the clinical or sociodemographic predictors for both successful and failed extubation among Chinese extremely and very preterm infants METHODS: A retrospective cohort study was carried out among extremely and very preterm infants born at less than 32 weeks of gestational age (GA).
Results:
Compared with the infants who experienced extubation failure, the successful infants had higher birth weight (OR 0.997; CI 0.996-0.998), higher GA (OR 0.582; 95% CI 0.499-0.678), a caesarean section delivery (OR 0.598; 95% CI 0.380-0.939), a higher five-minute Apgar score (OR 0.501; 95% CI 0.257-0.977), and a higher pH prior to extubation (OR 0.008; 95% CI 0.001-0.058). Failed extubation was associated with older mothers (OR 1.055; 95% CI 1.013-1.099), infants intubated in the delivery room (OR 2.820; 95% CI 1.742-4.563), a higher fraction of inspired oxygen (FiO2) prior to extubation (OR 5.246; 95% CI 2.540-10.835), higher partial pressure of carbon dioxide (PCO2) prior to extubation (OR 7.820; 95% CI 3.725-16.420), and higher amounts of lactic acid (OR 1.478;95% CI 1.063-2.056).
Conclusions:
Higher GA, higher pre-extubation pH, lower pre-extubation FiO2 and PCO, and lower age at extubation are significant predictors of successful extubation among extremely and very preterm infants.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...