Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Passive sampling hydrophilic and hydrophobic bisphenol analogues using hydrophilic-lipophilic balance
Xiaozhong Gao1, Juying Li2, Yiping Xu3
1State Key Laboratory of Heavy Oil Processing, State Key Laboratory of Petroleum Pollution Control, China University of Petroleum (Beijing), Beijing 102249, China; Shenzhen Key Laboratory of Environmental Chemistry and Ecological Remediation, College of Chemistry and Environmental Engineering, Shenzhen University,Shenzhen 518060, China.
Abstract:
Bisphenol analogues (BPs) are ubiquitous emerging contaminants in water environments and have wide polarity ranges (1.65 < log Kow < 7.2). Integrated passive sampling strategy rarely contains hydrophilic and hydrophobic organics simultaneously, while the method has good application perspective in monitoring organic contaminants. This work evaluated passive sampling performance for fifteen BPs in a newly developed passive sampler, i.e., hydrophilic-lipophilic balance sorbent-embedded cellulose acetate membrane (HECAM). In the dynamic accumulation experiments, both hydrophilic and hydrophobic BPs (including moderately hydrophilic BPs) well followed first-order kinetic uptake in the HECAMs. The estimated uptake rate constants, elimination rate constants, and equilibrium partition coefficients for BPs ranged from 4.4 L g-1 d-1 to 14.7 L g-1 d-1, 0.22 d-1 to 0.72 d-1, and 3.99 to 4.64, respectively. The kinetic parameters for BPs in HECAM show limited correlations to log Kow values, which the rule differs from traditional passive sampler. In the study of elimination kinetics, three deuterium labeled compounds showed incomplete elimination in HECAM and did not follow first-order isotropic exchange kinetics. Dual sorption mechanisms including both adsorption and partition were found for chemicals in HECAM, which the partitioned part could release to water and the adsorbed part could not easily release to water from HECAM. As a result, performance reference compounds (PRCs) calibration may be inapplicable to HLB sorbent-based passive sampler. The field deployment of HECAM in coastal waters of Guangdong, China resulted in the detection of eleven BPs, which indicated that the waters have been polluted by various BPs. Finally, monitoring strategy of simultaneous passive sampling hydrophobic and hydrophilic organic contaminants in surface waters was recommended.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
Related Concept Videos
Analyte Adsorption and Distribution
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...