Identification and assessment method of cable joint health status based on traveling wave reflection
Feng Zhou1, Fan Zhu1, Qiang Lyu2
1College of Electrical Engineering and Automation, Shandong University of Science and Technology, 579 Qianwangang Road, Huangdao, Qingdao, Shandong 266590, China.
Abstract:
Due to the difficulty in accurately detecting the health status of cable joints, a new method of identifying and assessing the cable joints' health status based on traveling wave reflection is proposed. By transmitting nanosecond pulse signals at the head end of the cable, the health status characteristics of the cable joints can be obtained, and the noise reduction of the measurement signals is performed by the wavelet function to identify the reflected wave at the joint and the end of the cable. The equivalent circuits and simulation models of contact resistance and leakage resistance are established, and the contact resistance and leakage resistance of the cable joints are calculated according to the amplitude and phase of the reflected signals at the joint and the end of the cable. By comparing with the resistance when the joint is in healthy operation, any measured parameter exceeding the corresponding standard is considered a joint fault. Simulations and test results show that the method can accurately identify the reflected signals of the cable joints in different operating states, and with changes in joint health, clear regular features can be extracted from the reflected signals, and the quality and health of the joints can be determined. The traveling wave method can be used to detect cable joint faults and provide an early warning of defects, which provides a new idea for online monitoring and early warning of cable joints in both theory and engineering practice.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
06:40Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Related Concept Videos
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load
Cable: Problem Solving
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...