Related Experiment Video
Updated: Sep 21, 2025

Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022
Simulation of Acute Pulmonary Hypertension in Beagle Dogs
Miao Wang1, YaTing Hu1, BinBin Guo1
1School of Biomedical Engineering, Dalian University of Technology.
Abstract:
Acoustic cardiography (AC) combined with heart sound (HS) recording and electrocardiogram (ECG) provides a noninvasive and inexpensive way to understand the electrical mechanical activity of the heart. Pulmonary artery stenosis can cause hemodynamic abnormalities that might lead to pulmonary hypertension (PH). In this paper, we examined the relationships between the acoustic characteristics of the AC and hemodynamic changes in a beagle dog model of PH.Four healthy beagle dogs were injected with the prostaglandin endoperoxide receptor agonist U-44069 to induce acute PH states. AC was employed to analyze the process of pre-PH, intra-PH, and post-PH. Right ventricular blood pressure (RVBP) was measured via right cardiac catheterization, an invasive method performed in parallel for comparative hemodynamic evaluation. As RVBP increased or decreased, the HS features changed accordingly during acute PH occurrence and development. Right ventricular systolic blood pressure (RVSBP) significantly correlated with the minimum of the first HS (S1) amplitude (correlation coefficient (CC) = -0.82), energy of the S1 (CC = 0.86), energy of the second HS (S2) (CC = 0.67), entropy of the S1 (CC = -0.94), and ratio of electromechanical systolic time (EMST) to the cardiac cycle time (CC = 0.81). The two techniques (AC [HSs and ECG] versus right cardiac catheterization [RVBP]) were significantly correlated. Especially, the diastolic filling time (DFT) had a significant relationship with the right ventricular diastolic time (RVDT) (CC = 0.97), perfusion time (PT) (CC = 0.96), and cardiac cycle time (RR) (CC = 0.96). The CCs between the RVDT and the max dp/dt to min dp/dt, the EMST and the Q to min dp/dt, and the electromechanical activation time and the Q to max dp/dt were 0.95, 0.99, and 0.86, respectively. Furthermore, the logistic regression model with different combinations was used to identify the effective features for monitoring hemodynamic and pathophysiologic conditions.AC provided significant insight into mechanical dysfunction in a rapid and noninvasive way that could be used for early screening of PH.
More Related Videos
07:02A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep
Published on: July 15, 2021
07:41Induction and Phenotyping of Acute Right Heart Failure in a Large Animal Model of Chronic Thromboembolic Pulmonary Hypertension
Published on: March 17, 2022