Related Experiment Video
Updated: Sep 21, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Adding false-profile radiographs improves detection of developmental dysplasia of the hip, data from the CHECK cohort
Julie Herfkens1, Michiel M A van Buuren1, Noortje S Riedstra1
1Department of Orthopaedics and Sports Medicine, Erasmus University Medical Center, Rotterdam, Zuid-Holland, The Netherlands.
Abstract:
The aim of this study was to determine the additional value of the false-profile (FP) view radiograph in the diagnosis of developmental dysplasia of the hip (DDH), as compared with an anteroposterior (AP) pelvic radiograph only, and evaluate the correlation between the Wiberg-lateral center edge angle (W-LCEA) and Wiberg-anterior center edge angle (W-ACEA). We used baseline data from a nationwide prospective cohort study (Cohort Hip and Cohort Knee). DDH was quantified on AP pelvic and FP hip radiographs using semi-automatic measurements of the W-LCEA and W-ACEA. A threshold of <20° was used to determine DDH for both the W-LCEA and the W-ACEA. The proportion of DDH only present on the FP view determined the FP view additional value. The correlation between the W-LCEA and W-ACEA was determined. In total 720 participants (1391 hips) were included. DDH was present in 74 hips (5.3%), of which 32 were only present on the FP view radiograph (43.2%). The Pearson correlation coefficient between W-LCEA and W-ACEA of all included hips was 0.547 (95% confidence interval: 0.503-0.591) and 0.441 (95% confidence interval: 0.231-0.652) in hips with DDH. A mean difference of 9.4° (SD 8.09) was present between the W-LCEA and the W-ACEA in the hips with DDH. There is a strong additional value of the FP radiograph in the diagnosis of DDH. Over 4 out of 10 (43.2%) individuals' DDH will be missed when only using the AP radiograph. In hips with DDH a moderate correlation between W-LCEA and W-ACEA was calculated indicating that joints with normal acetabular coverage on the AP view can still be undercovered on the FP view.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging

