Related Experiment Video
Updated: Jul 4, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator
Vincenzo Russo1,2, Anna Rago2, Vincenzo Ruggiero1
1Cardiology Unit, Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli", Monaldi Hospital, Naples, Italy.
Introduction:
In the context of randomized clinical trials, subcutaneous implantable cardiac defibrillators (S-ICDs) are non-inferior to transvenous ICDs (T-ICDs) concerning device-related complications or inappropriate shocks in patients with an indication for defibrillator therapy and not in need of pacing. We aimed at describing the clinical features of patients who underwent S-ICD implantation in our clinical practice, as well as the ICD-related complications and the inappropriate therapies among S-ICD vs. T-ICD recipients during a long-term follow-up.
Materials And Methods:
All patients undergoing ICD, both S-ICD and TV-ICD, at Monaldi Hospital from January 1, 2015 to January 1, 2019 and followed up at our institution were included in the present analysis. The clinical variables associated with S-ICD implantation were evaluated by logistic regression analyses. We collected the ICD inappropriate therapies, ICD-related complications (including both pulse generator and lead-related complications), ICD-related infections, appropriate ICD therapies, and overall mortality. Kaplan-Meier (KM) analyses were performed to assess the risk of clinical outcome events between the two subgroups. A time-dependent Cox regression analysis was performed to adjust the results.
Results:
Total 607 consecutive patients (mean age 53.8 ± 16.8, male 77.8%) with both TV-ICD (n: 290, 47.8%) and S-ICD (n: 317, 52.2%), implanted and followed at our center for a mean follow-up of 1614 ± 1018 days, were included in the study. At multivariate logistic regression analysis, an independent association between S-ICD implantation and ionic channel disease [OR: 6.01 (2.26-15.87); p < 0.0001] and ischemic cardiomyopathy [OR: 0.20 (0.12-0.35); p < 0.0001] was shown. The KM analysis did not show a significantly different risk of the inappropriate ICD therapies (log rank p = 0.64) between the two subgroups; conversely, a significant increase in the risk of ICD-related complications (log rank p = 0.02) and infections (log rank p = 0.02) in TV-ICD group was shown. The adjusted risk for ICD-related infections [OR: 0.07 (0.009-0.55), p = 0.01] and complications [0.31 (0.12-0.81), p = 0.01] was significantly lower among patients with S-ICD.
Conclusions:
The choice to implant S-ICD was mainly driven by younger age and the presence of ionic channel disease; conversely ischemic cardiomyopathy reduces the probability to use this technology. No significant differences in inappropriate ICD therapies were shown among S-ICD vs. TV-ICD group; moreover, S-ICD is characterized by a lower rate of infectious and non-infectious complications leading to surgical revision or extraction.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Catheterization IV: Nursing Management
Heart Failure VI: Adjunct Therapies
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy V: Interprofessional Care
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

