Related Experiment Video
Updated: Sep 21, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Nasogastric tube in mechanical ventilated patients: ETCO2 and pH measuring to confirm correct placement. A pilot
Samuele Ceruti1, Simone Dell'Era2, Francesco Ruggiero3
1Department of Critical Care, Clinica Luganese Moncucco, Lugano, Ticino, Switzerland.
Introduction:
Nasogastric tube (NGT) placement is a procedure commonly performed in mechanically ventilated (MV) patients. Chest X-Ray is the diagnostic gold-standard to confirm its correct placement, with the downsides of requiring MV patients' mobilization and of intrinsic actinic risk. Other potential methods to confirm NGT placement have shown lower accuracy compared to chest X-ray; end-tidal CO2 (ETCO2) and pH analysis have already been singularly investigated as an alternative to the gold standard. Aim of this study was to determine threshold values in ETCO2 and pH measurement at which correct NGT positioning can be confirmed with the highest accuracy.
Materials & Methods:
This was a prospective, multicenter, observational trial; a continuous cohort of eligible patients was allocated with site into two arms. Patients underwent general anesthesia, orotracheal intubation and MV; in the first and second group we respectively assessed the difference between tracheal and esophageal ETCO2 and between esophageal and gastric pH values.
Results:
From November 2020 to March 2021, 85 consecutive patients were enrolled: 40 in the ETCO2 group and 45 in the pH group. The ETCO2 ROC analysis for predicting NGT tracheal misplacement demonstrated an optimal ETCO2 cutoff value of 25.5 mmHg, with both sensitivity and specificity reaching 1.0 (AUC 1.0, p < 0.001). The pH ROC analysis for predicting NGT correct gastric placement resulted in an optimal pH cutoff value of 4.25, with mild diagnostic accuracy (AUC 0.79, p < 0.001).
Discussion:
In patients receiving MV, ETCO2 and pH measurements respectively identified incorrect and correct NGT placement, allowing the identification of threshold values potentially able to improve correct NGT positioning.
Trial Registration:
NCT03934515 (www.clinicaltrials.gov).
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Enteral Nutrition I: Orogastric and Nasogastric Feeding
Orogastric (OG) and nasogastric (NG) feeding are two standard methods used for enteral nutrition. Enteral nutrition is often preferred over...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...