Related Experiment Video
Updated: Sep 21, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Masked Joint Bilateral Filtering via Deep Image Prior for Digital X-Ray Image Denoising
Abstract:
Medical image denoising faces great challenges. Although deep learning methods have shown great potential, their efficiency is severely affected by millions of trainable parameters. The non-linearity of neural networks also makes them difficult to be understood. Therefore, existing deep learning methods have been sparingly applied to clinical tasks. To this end, we integrate known filtering operators into deep learning and propose a novel Masked Joint Bilateral Filtering (MJBF) via deep image prior for digital X-ray image denoising. Specifically, MJBF consists of a deep image prior generator and an iterative filtering block. The deep image prior generator produces plentiful image priors by a multi-scale fusion network. The generated image priors serve as the guidance for the iterative filtering block, which is utilized for the actual edge-preserving denoising. The iterative filtering block contains three trainable Joint Bilateral Filters (JBFs), each with only 18 trainable parameters. Moreover, a masking strategy is introduced to reduce redundancy and improve the understanding of the proposed network. Experimental results on the ChestX-ray14 dataset and real data show that the proposed MJBF has achieved superior performance in terms of noise suppression and edge preservation. Tests on the portability of the proposed method demonstrate that this denoising modality is simple yet effective, and could have a clinical impact on medical imaging in the future.
Related Concept Videos
X-ray Imaging
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...