Related Experiment Video
Updated: Sep 21, 2025

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Serum and urine osmolality: 8 hours, 24 hours and 1-month sample stability
Anamarija Đuras1, Valentina Cesar Kocijan1, Anamarija Rade1
1Department of Medical Biochemistry Laboratory, General Hospital Varaždin, Varaždin, Croatia.
Objectives:
The body of literature varies significantly regarding serum and urine osmolality stability. Therefore, our aim was to investigate the stability of serum and urine osmolality at different temperatures (room temperature (RT) 4-8 °C, -20 °C) and time conditions (8 h, 24 h, 1 month).
Methods:
The stability study was conducted following the CRESS guidelines, including 40 serum and urine samples. Samples were aliquoted into three aliquots and stored as follows: primary tube stored at RT for 8 h; two capped aliquots stored at 4-8 °C for 8 h and 24 h; one aliquot stored at -20 °C for 1 month. To minimize imprecision error, serum and urine osmolality were measured by the freezing point depression method in triplicate on OSMOMAT 3000 (Gonotech, Germany) analyzer. Percentage difference (PD%) against baseline measurement was calculated. Deviations were assessed against a reference change value of 5.0%.
Results:
The PD% for serum and urine osmolality was below 2.0% for all time/temperature conditions. For serum samples: primary tube after 8 h at RT PD% (95% CI) = 0.0% (-0.3, 0.2%); 8 h at 4-8 °C PD% (95% CI) = -0.4% (-0.7, 0.0%); 24 h at 4-8 °C PD% (95% CI) = -0.7% (-0.7, -0.6%); 1 month at -20 °C PD% (95% CI) = -2.1% (-2.4, -1.5%). For urine samples: after 8 h at RT PD% (95% CI) =0.6% (0.2, 0.9%); 8 h at 4-8 °C PD% (95% CI) = -0.2% (-0.5, 0.1%); 24 h at 4-8 °C PD% (95% CI) = -0.2% (-0.5, 0.0%); 1 month at -20 °C PD% (95% CI) = -2.0% (-3.0, -1.0%).
Conclusions:
Changes in osmolality for tested conditions for serum and urine samples, were within acceptance criteria. Reflex and add-on osmolality testing can be performed within the same day in samples kept at RT for 8 h in primary tube and within 24 h, in aliquoted refrigerated samples, without compromising the reliability of test results. For longer storage, samples should be kept at -20 °C.
Related Concept Videos
Serum Studies: Renal Function Tests
Urine Studies I: Urinalysis
Osmosis and Osmotic Pressure of Solutions
Formation of Concentrated Urine
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Urine: Physical and Chemical Properties
The concentration of these solutes varies, with urea being the most abundant nitrogenous waste product. Other solutes include sodium, chloride, potassium, phosphate,...