Related Experiment Video
Updated: Sep 21, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Feasibility study of defecation studied with a wireless Fecobionics probe in normal subjects
Hans Gregersen1, Yanmin Wang1, Fred Field2
1California Medical Innovations Institute, San Diego, California, USA.
Abstract:
Several technologies have been developed for assessing anorectal function including the act of defecation. We used a new prototype of the Fecobionics technology, a multi-sensor simulated feces, to visualize defecatory patterns and introduced new metrics for anorectal physiology assessment in normal subjects. Fourteen subjects with normal fecal incontinence and constipation questionnaire scores were studied. The 10-cm-long Fecobionics device provided measurements of axial pressures, orientation, bending, and shape. The Fecobionics bag was distended to the urge-to-defecate level inside rectum where after the subjects were asked to evacuate. Physiological evacuation parameters were assessed. Special attention was paid to the Fecobionics rectoanal pressure gradient (F-RAPG) during evacuation. Anorectal manometry (ARM) and balloon expulsion test (BET) were done as references. The user interface displayed the fine coordination between pressures, orientation, bending angle, and shape. The pressures showed that Fecobionics was expelled in 11.5 s (quartiles 7.5 and 18.8s), which was shorter than the subjectively reported expulsion time of the BET balloon. Six subjects did not expel the BET balloon within 2 min. The F-RAPG was 101 (79-131) cmH2 O, whereas the ARM-RAPG was -28 (-5 to -47) cmH2 0 (p < 0.001). There was no association between the two RAPGs (r2 = 0.19). Fecobionics showed paradoxical contractions in one subject (7%) compared to 12 subjects with ARM (86%). Fecobionics obtained novel physiological data. Defecatory patterns and data are reported and can be used to guide larger-scale studies in normal subjects and patients with defecatory disorders. In accordance with other studies, this Fecobionics study questions the value of the ARM-RAPG.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
08:17Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018
Related Concept Videos
Feces Formation and Defecation
The mass peristalsis then pushes the feces into the rectum, which stretches the rectal walls to activate...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...