Inactivation of biohazards in healthcare wastewater by E-Beam and Gamma irradiation: a comparative study
Sihem Jebri1, Mariem Yahya2, Faten Rahmani2
1Laboratoire de Biotechnologies Et Techniques Nucléaires, CNSTN, Technopôle de Sidi Thabet, 2020, Sidi Thabet, Tunisia. sihem.arrows@gmail.com.
Abstract:
The main objective of this study is to evaluate the effect of irradiation by Gamma rays and Electron Beam (E-Beam) on naturally occurring microorganisms shed in healthcare wastewater issued from multi-specialties hospital. We examined the susceptibility of naturally occurring total indicator bacteriophages towards Gamma rays and E-Beam irradiation to evaluate their appropriateness as viral indicators for healthcare wastewater quality control. Results showed that healthcare wastewater is a rich matrix containing bacteriophages surrogates of pathogenic waterborne viruses (4.5 Log10 PFU/100 mL for SOMCPH and 2.3 Log10 PFU/100 mL for FRNAPH), antibiotic resistant bacteria (Mean concentrations from 2.3 to 5.5 Log10 CFU/100 mL), molds and yeasts (2.7 Log10 CFU/100 mL), and spores of Clostridium perfringens (Mean concentration of 3.3 Log10 CFU/100 mL). After E-Beam irradiation, naturally occurring bacteria in healthcare wastewater showed lower resistance patterns (D10 values ranging between 0.21 ± 0.005 and 0.59 ± 0.005) compared to those obtained after Gamma irradiation (D10 values ranging between 0.25 ± 0.015 and 0.70 ± 0.0001). Spores of Clostridium perfringens were the most resistant assayed microbes either after E-Beam (D10 values of 3.74 ± 0.005) or Gamma irradiation (D10 values of 4.77 ± 0.025) of collected samples. According to inactivation patterns, a dose of 10 kGy was sufficient for a complete inactivation of spores. Bacteriophages isolated from healthcare wastewater showed the same resistance patterns as those previously obtained in urban treated sewage and were inactivated using higher doses than waterborne bacteria (D10 values of SOMCPH 1.46 ± 0.057; D10 values of FRNAPH 1.03 ± 0.057). Their resistance to irradiation treatment in such complex matrix corroborates their use to survey the viral quality of healthcare wastewater before their discharge in the urban sanitation network. D10 value analysis showed that bacteria and bacteriophages inactivation by E-Beam irradiation required lower doses than those required for their inactivation using Gamma rays. According to inactivation patterns, a dose of 7 kGy was sufficient for total inactivation of both pathogenic bacteria and viruses. Thus, E-Beam irradiation seems to be an efficient physical pre-treatment process for healthcare wastewater treatment prior to its discharge in urban sanitation system to ensure compliance with environmental standards and protect public health.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Biological Effects of Radiation
Physical Methods for Controlling Microbial Growth: Temperature


