Related Experiment Video
Updated: Sep 21, 2025

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Calibration of miniature air quality detector monitoring data with PCA-RVM-NAR combination model
1Public Foundational Courses Department, Nanjing Vocational University of Industry Technology, Nanjing, 210023, China. Liub1@niit.edu.cn.
Abstract:
The development of miniature air quality detectors makes it possible for humans to monitor air quality in real time and grid. However, the accuracy of measuring pollutants by miniature air quality detectors needs to be improved. In this paper, the PCA-RVM-NAR combined model is proposed to calibrate the measurement accuracy of the miniature air quality detector. First, correlation analysis is used to find out the main factors affecting pollutant concentrations. Second, principal component analysis is used to reduce the dimensionality of these main factors and extract their main information. Thirdly, taking the extracted principal components as independent variables and the observed values of pollutant concentrations as dependent variables, a PCA-RVM model is established by the relevance vector machine. Finally, the nonlinear autoregressive neural network is used to correct the error and finally complete the establishment of the PCA-RVM-NAR model. Root mean square error, goodness of fit, mean absolute error and relative mean absolute percent error are used to compare the calibration effect of PCA-RVM-NAR model and other commonly used models such as multiple linear regression model, support vector machine, multilayer perceptron neural network and nonlinear autoregressive models with exogenous input. The results show that, no matter which pollutant, the PCA-RVM-NAR model achieves better calibration results than other models in the four indicators. Using this model to correct the data of the miniature air quality detector can improve its accuracy by 77.8-93.9%.
More Related Videos
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

