Deep Neuromuscular Blockade Leads to a Larger Intraabdominal Volume During Laparoscopy
Published on: June 25, 2013
Prediction of blood pressure changes associated with abdominal pressure changes during robotic laparoscopic low
Yang-Hoon Chung1, Young-Seob Jeong2, Gati Lother Martin3
1Department of Anesthesiology and Pain Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Republic of Korea.
Background:
Intraoperative hypertension and blood pressure (BP) fluctuation are known to be associated with negative patient outcomes. During robotic lower abdominal surgery, the patient's abdominal cavity is filled with CO2, and the patient's head is steeply positioned toward the floor (Trendelenburg position). Pneumoperitoneum and the Trendelenburg position together with physiological alterations during anesthesia, interfere with predicting BP changes. Recently, deep learning using recurrent neural networks (RNN) was shown to be effective in predicting intraoperative BP. A model for predicting BP rise was designed using RNN under special scenarios during robotic laparoscopic surgery and its accuracy was tested.
Methods:
Databases that included adult patients (over 19 years old) undergoing low abdominal da Vinci robotic surgery (ovarian cystectomy, hysterectomy, myomectomy, prostatectomy, and salpingo-oophorectomy) at Soonchunhyang University Bucheon Hospital from October 2018 to March 2021 were used. An RNN-based model was designed using Python3 language with the PyTorch packages. The model was trained to predict whether hypertension (20% increase in the mean BP from baseline) would develop within 10 minutes after pneumoperitoneum.
Results:
Eight distinct datasets were generated and the predictive power was compared. The macro-average F1 scores of the datasets ranged from 68.18% to 72.33%. It took only 3.472 milliseconds to obtain 39 prediction outputs.
Conclusions:
A prediction model using the RNN may predict BP rises during robotic laparoscopic surgery.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...