Elution with 1,2-Hexanediol Enables Coupling of ICPMS with Reversed-Pase Liquid Chromatography under Standard
Bassam Lajin1, Joerg Feldmann2, Walter Goessler1
1Institute of Chemistry, Analytical Chemistry for the Health and Environment, University of Graz, Universitaetsplatz 1, 8010 Graz, Austria.
Abstract:
The inductively coupled plasma mass spectrometry (ICPMS) has been attracting increasing attention for many applications as an element-selective chromatographic detector. A major and fundamental limitation in coupling ICPMS with liquid chromatography is the limited compatibility with organic solvents, which has so far been addressed via a tedious approach, collectively referred to as the "organic ICPMS mode", that can decrease detection sensitivity by up to 100-fold. Herein, we report 1,2-hexanediol as a new eluent in high-performance liquid chromatography-ICPMS which enables avoiding the current limitations. Unlike commonly used eluents, 1,2-hexanediol was remarkably compatible with ICPMS detection at high flow rates of 1.5 mL min-1 and concentrations of at least 30% v/v, respectively, under the standard conditions and instrumental setup normally used with 100% aqueous media. Sensitivity for all tested elements (P, S, Cl, Br, Se, and As) was enhanced with 10% v/v 1,2-hexanediol relative to that of 100% aqueous media by 1.5-7-fold depending on the element. Concentrations of 1,2-hexanediol at ≤30% v/v were superior in elution strength to concentrations at >90% v/v of the common organic phases, which greatly decreases the amount of carbon required to elute highly hydrophobic compounds such as lipids and steroids, enabling detection at ultra-trace levels. The proposed approach was applied to detect arsenic-containing fatty acids in spiked human urine, and detection limits of <0.01 μg As L-1 were achieved, which is >100-fold lower than those previously reported using the organic ICPMS mode. Nontargeted speciation analysis in Allium sativum revealed the presence of a large number of hydrophobic sulfur-containing metabolomic features at trace levels.
More Related Videos
09:22Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...