Gas- and Particle-Phase Amide Emissions from Cooking: Mechanisms and Air Quality Impacts

Jenna C Ditto1,2, Jonathan P D Abbatt2, Arthur W H Chan1,2

  • 1Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON M5S 3E5, Canada.

Related Concept Videos

2° Amines to N-Nitrosamines: Reaction with NaNO201:20

2° Amines to N-Nitrosamines: Reaction with NaNO2

Secondary amines react with nitrous acid to form N-nitrosamines, as depicted in Figure 1. Nitrous acid, a weak and unstable acid, is formed in situ from an aqueous solution of sodium nitrite and strong acids, such as hydrochloric acid or sulfuric acid, in cold conditions. In the presence of an acid, the nitrous acid gets protonated. The subsequent loss of water results in the formation of the electrophile known as nitrosonium ion.
4.6K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
288
Carboxylic Acids to Methylesters: Alkylation using Diazomethane01:33

Carboxylic Acids to Methylesters: Alkylation using Diazomethane

Carboxylic acids react with diazomethane in an ether solvent via alkylation at the carboxylate oxygen atom to give methyl esters of the corresponding acid with excellent yields.
2.4K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
528
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
682
Mass Spectrometry of Amines01:19

Mass Spectrometry of Amines

In mass spectroscopy, amines undergo fragmentation to give parent ions with odd molecule weights. This observed mass spectrum follows the nitrogen rule: a molecule with an odd number of nitrogen atoms produces a parent ion with an odd molecular weight. The remaining fragments have an even mass.
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...
4.4K