Evaluation of Hepatic Hemodynamics (Hepatic Venous Pressure Gradient) During Right Heart Catheterization: A

Guillermo Cueto-Robledo1, Abril Tapia-Paredes2, Marisol Garcia-Cesar3

  • 1Cardiorespiratory Emergencies, Hospital General de Mexico "Dr. Eduardo Liceaga", Mexico City, Mexico; Pulmonary Circulation Clinic, Hospital General de Mexico "Dr. Eduardo Liceaga", Mexico City, Mexico; Faculty of Medicine, National Autonomous University of Mexico, Mexico City, Mexico.

Related Concept Videos

Cardiac Catheterization II: Right Heart Catheterization01:21

Cardiac Catheterization II: Right Heart Catheterization

Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...
185
Cardiac Catheterization I: Pre-Procedure Overview01:28

Cardiac Catheterization I: Pre-Procedure Overview

Cardiac catheterization is an invasive diagnostic technique used to identify and evaluate structural and functional diseases of the heart and major blood vessels. This technique diagnoses congenital heart disease, coronary artery disease, valvular heart disease, and coronary spasms and assesses ventricular function. It helps guide treatment decisions, including the need for revascularization procedures like percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) and...
187
Cardiac Catheterization III: Left Heart Catheterization01:24

Cardiac Catheterization III: Left Heart Catheterization

Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
236
Assessment of the Cardiovascular System III: Palpation01:27

Assessment of the Cardiovascular System III: Palpation

Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
505
Cardiac Catheterization IV: Nursing Management01:26

Cardiac Catheterization IV: Nursing Management

Nursing responsibilities before cardiac catheterization include:Assess for allergies and establish baseline health status.Before cardiac catheterization, assess the patient for allergies to contrast dye. Perform a comprehensive baseline assessment, including vital signs, heart and breath sounds, and a neurovascular assessment of the extremities, noting distal pulses, skin color, and temperature. Instruct the patient to fast for 8-12 hours before the procedure. Evaluate baseline laboratory...
211
Imbalances in Cardiac Output01:26

Imbalances in Cardiac Output

The heart's primary function is to pump blood throughout the body, maintaining a balance between blood sent out (cardiac output) and blood returning (venous return). If this balance is disrupted, it can result in congestive heart failure (CHF), a severe condition where the heart becomes an inefficient pump, leading to inadequate blood circulation.
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
1.6K