Cost increase in the electricity supply to achieve carbon neutrality in China

Zhenyu Zhuo1, Ershun Du2, Ning Zhang3

  • 1Department of Electrical Engineering, Tsinghua University, Beijing, 100084, China.

Related Concept Videos

Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
275
Electrical Energy01:10

Electrical Energy

Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.3K
Global Climate Change01:50

Global Climate Change

Throughout its ~4.5 billion year history, the Earth has experienced periods of warming and cooling. However, the current drastic increase in global temperatures is well outside of the Earth’s cyclic norms, and evidence for human-caused global climate change is compelling. Paleoclimatology, the study of ancient climate conditions, provides ample evidence for human-caused global climate change by comparing recent conditions with those in the past.
24.8K
Capacitance: Single-Phase And Three-Phase Line01:25

Capacitance: Single-Phase And Three-Phase Line

In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
229
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
207
Energy Conservation and Bernoulli's Equation01:16

Energy Conservation and Bernoulli's Equation

Applying the conservation of energy principle or the work-energy theorem to an incompressible, inviscid fluid in laminar, steady, irrotational flow leads to Bernoulli's equation. It states that the sum of the fluid pressure, potential, and kinetic energy per unit volume is constant along a streamline.
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
9.5K