Related Experiment Video
Updated: Sep 20, 2025

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
Discrepancy Between Invasive and Noninvasive Blood Pressure Measurements in Patients with Sepsis by Vasopressor
Quincy K Tran1, Dominique Gelmann2, Zain Alam2
1University of Maryland School of Medicine, The R Adams Cowley Shock Trauma Center, Baltimore, Maryland.
Introduction:
Blood pressure (BP) monitoring is an essential component of sepsis management. The Surviving Sepsis Guidelines recommend invasive arterial BP (IABP) monitoring, although the benefits over non-invasive BP (NIBP) monitoring are unclear. This study investigated discrepancies between IABP and NIBP measurement and their clinical significance. We hypothesized that IABP monitoring would be associated with changes in management among patients with sepsis requiring vasopressors.
Methods:
We performed a retrospective study of adult patients admitted to the critical care resuscitation unit at a quaternary medical center between January 1-December 31, 2017. We included patients with sepsis conditions AND IABP monitoring. We defined a clinically significant BP discrepancy (BPD) between NIBP and IABP measurement as a difference of > 10 millimeters of mercury (mm Hg) AND change of BP management to maintain mean arterial pressure ≥ 65 mm Hg.
Results:
We analyzed 127 patients. Among 57 (45%) requiring vasopressors, 9 (16%) patients had a clinically significant BPD vs 2 patients (3% odds ratio [OR] 6.4; 95% CI: 1.2-30; P = 0.01) without vasopressors. In multivariable logistic regression, higher Sequential Organ Failure Assessment (SOFA) score (OR 1.33; 95% CI: 1.02-1.73; P = 0.03) and serum lactate (OR 1.27; 95% CI: 1.003-1.60, P = 0.04) were associated with increased likelihood of clinically significant BPD. There were no complications (95% CI: 0-0.02) from arterial catheter insertions.
Conclusion:
Among our population of septic patients, the use of vasopressors was associated with increased odds of a clinically significant blood pressure discrepancy between IABP and NIBP measurement. Additionally, higher SOFA score and serum lactate were associated with higher likelihood of clinically significant blood pressure discrepancy. Further studies are needed to confirm our observations and investigate the benefits vs the risk of harm of IABP monitoring in patients with sepsis.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...