Related Experiment Video
Updated: Sep 20, 2025

Adaptation of Semiautomated Circulating Tumor Cell CTC Assays for Clinical and Preclinical Research Applications
Published on: February 28, 2014
DNA walker-powered ratiometric SERS cytosensor of circulating tumor cells with single-cell sensitivity
Jingrong Xiong1, Chen Dong1, Jingjing Zhang1
1State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, Nanjing, 210023, China.
Abstract:
Identification and detection of extreme rare circulating tumor cells (CTCs) in peripheral blood can precisely monitor cancer recurrence and metastasis, however, how to ultra-sensitively and reliably detect CTCs is a big challenge. In this work, a ratiometric surface-enhanced Raman spectroscopy (SERS)-based strategy for ultra-sensitively and nondestructively detecting CTCs was proposed via CTCs-triggered DNA walker-assisted assembly of plasmonic nanostructure networks consisting of Walker probes and SERS tags. The Walker probes were prepared by modifying Fe3O4@SiO2@Au nanoparticles (GMNPs) with ROX-labeled EpCAM aptamer-blocked Zn2+-specific DNAzyme and hairpin-structured single-stranded DNAs H1, and the SERS tags were constructed by co-labelling hairpin-structured single-stranded DNAs H2 and Raman molecules (DTNB) on Au NPs. The aptamers can recognize EpCAM-positive CTCs via the specific binding to EpCAM, so that the activity of DNAzymes is activated with the assistance of Zn2+ to launch the DNA walker to move around for the cleavage of H1 on GMNPs. The residual fragments of H1 on GMNPs can hybridize with H2 on SERS tags and result in the formation of Walker probe-SERS tag network nanostructures (Nw NSs) with rich SERS hot spots. The reliable SERS detection of CTCs is achieved by the stable ratiometric SERS signals of DTNB and ROX generated from the Nw NSs, and a good linear relation between ratiometric SERS signal and MCF-7 cells concentration was obtained with the detection limit low to 1 cell/mL. The recovery rate of MCF-7 cells in peripheral blood is in the range of 94.0%-104.5%, which indicates a good application prospect of the novel ratiometric SERS cytosensor in the clinic detection of EpCAM-positive CTCs.
More Related Videos
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019
05:17Micromanipulation of Circulating Tumor Cells for Downstream Molecular Analysis and Metastatic Potential Assessment
Published on: May 14, 2019