Summary
Resolute Onyx zotarolimus-eluting stents (ZES) showed similar safety and effectiveness to BioFreedom biolimus A9-coated stents (DCS) in high-bleeding-risk patients after 1-month dual antiplatelet therapy (DAPT). Two-year results confirm noninferiority for both stent types in this patient group.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Biomaterials Science
Background:
- High-bleeding-risk (HBR) patients require careful antiplatelet therapy management after percutaneous coronary intervention.
- Comparing polymer-based zotarolimus-eluting stents (ZES) with polymer-free biolimus A9-coated stents (DCS) is crucial for optimizing treatment strategies.
Purpose of the Study:
- To report the final 2-year outcomes of the Onyx ONE trial, comparing Resolute Onyx ZES with BioFreedom DCS.
- To evaluate the safety and effectiveness of a 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) regimen in HBR patients.
Main Methods:
- The Onyx ONE randomized controlled trial enrolled HBR patients assigned to ZES or DCS.
- Patients received 1-month DAPT, followed by SAPT if event-free.
- Primary safety and secondary effectiveness endpoints were assessed at 1 and 2 years.
Main Results:
- A total of 1,003 patients received ZES and 993 received DCS, with high follow-up rates at 2 years.
- The primary safety endpoint occurred in 21.2% of ZES patients and 20.7% of DCS patients (P=0.78).
- The secondary effectiveness endpoint occurred in 22.1% of ZES patients and 21.0% of DCS patients (P=0.54).
Conclusions:
- Resolute Onyx ZES demonstrated similar 2-year safety and effectiveness compared to BioFreedom DCS in HBR patients on a 1-month DAPT regimen.
- These findings support the use of both stent types in HBR patients undergoing short-term DAPT.
Keywords:
drug-coated stent(s)drug-eluting stent(s)high bleeding riskpercutaneous coronary intervention