Related Experiment Video
Updated: Sep 20, 2025

Single Liposome Measurements for the Study of Proton-Pumping Membrane Enzymes Using Electrochemistry and Fluorescent Microscopy
Published on: February 21, 2019
Proton-Gradient-Driven Sensitivity Enhancement of Liposome-Encapsulated Supramolecular Chemosensors
Mohamed Nilam1,2, Shreya Karmacharya2, Werner M Nau2
1Center for Cellular Nanoanalytics (CellNanOs) and Department of Biology and Chemistry, Universität Osnabrück, Barbarastraße 7, 49069, Osnabrück, Germany.
Abstract:
An overarching challenge in the development of supramolecular sensor systems is to enhance their sensitivity, which commonly involves the synthesis of refined receptors with increased affinity to the analyte. We show that a dramatic sensitivity increase by 1-2 orders of magnitude can be achieved by encapsulating supramolecular chemosensors inside liposomes and exposing them to a pH gradient across the lipid bilayer membrane. This causes an imbalance of the influx and efflux rates of basic and acidic analytes leading to a significantly increased concentration of the analyte in the liposome interior. The utility of our liposome-enhanced sensors was demonstrated with various host-dye reporter pairs and sensing mechanisms, and we could easily increase the sensitivity towards multiple biologically relevant analytes, including the neurotransmitters serotonin and tryptamine.