A method for assessing and monitoring consistency of nonclinical ECG analysis
Rebecca A Ross1, C Michael Foley2, Hilton M Jones1
1Labcorp Early Development Laboratories Inc, 3301 Kinsman Boulevard, Madison, WI 53704, USA.
Abstract:
Cardiovascular safety is a key area of concern for new drugs in development, and the collection and analysis of electrocardiograms (ECGs) is a standard and major component of nonclinical testing. Digital data capture technology allows for high-throughput and long-duration ECG collections, resulting in large volumes of data. Consistent analysis of these ECG data is critical for detecting meaningful changes during nonclinical drug development. We developed a method to assess the consistency of nonclinical ECG analysis for a group of analysts over time. Eight‑lead ECGs were collected from conscious dogs using Ponemah (v5.2, DSI). Analysts placed Pstart, Qstart, Rpeak, Send, and Tend marks on six waveforms for each animal. The ECG files were randomized and re-marked under blinded conditions 4 to 14 days following initial mark placement. Averages of each parameter measured (RR interval, QRS duration, PR interval, and QT interval) were compiled for each marking session and analyst. A Gage R&R evaluation was completed. Graphical output from the Gage R&R evaluation showed distinct variability on group and individual analyst levels. Differences in inter- and intra-analyst variability (reproducibility and repeatability, respectively) were observed between trained analysts and analysts in training. The Gage R&R method is an effective tool for assessing consistency of digital ECG mark placement at a group level. Furthermore, it is able to identify areas of improvement for individual ECG analysts and to assess ECG analyst consistency during their training period. The assessment results are useful for facilitating discussions on best practices and maintaining consistency of mark placement.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias V: Evaluating Dysrhythmias