Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
Mohamed Abdel-Wahed1, Ahmed Abdel-Zaher Khater2, Mahmoud Ahmed El-Desouky3
1Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt.
Purpose:
Two different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs.
Methods:
We reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients' mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months.
Results:
All patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score.
Conclusion:
Distal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...