Real world hypoglycaemia related to glucose variability and Flash glucose scan frequency assessed from global
Jean-Pierre Riveline1,2, Anne Wojtusciszyn3, Bruno Guerci4
1Department of Diabetology and Endocrinology, Hôpital Lariboisière, APHP, Paris, France.
Aim:
Flash glucose monitoring provides a range of glucose metrics. In the current study, we aim to identify those that indicate that glycaemic targets can be consistently met and contrast the total (t-CV) and within-day coefficient of variation (wd-CV) to guide the assessment of glucose variability and hypoglycaemia exposure.
Methods:
De-identified data from Flash readers were collected. The readers were sorted into 10 equally sized groups of scan frequency followed by quartiles of estimated A1c (eA1c). A similar grouping was performed for the total coefficient of variation (t-CV) and within-day coefficient of variation (wd-CV). In addition, analysis of the association of time below 54 mg/dl and glucose variability measured by t-CV and wd-CV was performed.
Results:
The dataset included 1 002 946 readers. Readers sorted by 10 equal groups of scan rate and quartiles by eA1c, t-CV and wd-CV represented 25 074 readers per group. The association of lower eA1c with higher time in range and reduced time above range was clear. The correlation of eA1c quartiles and time below range was not consistent. An association between glucose variability and hypoglycaemia was found. Both wd-CV and t-CV were associated with time below range. For achieving the consensus target of <1% time below 54 mg/dl, the associated wd-CV and t-CV values were 33.5% and 39.5%, respectively.
Conclusions:
The type of CV reported by the different continuous glucose monitoring systems should be acknowledged. CV <36% might not be adequate to ensure low hypoglycaemia exposure. To our knowledge, the majority of continuous glucose monitoring reports the t-CV. Appropriate thresholds should be used to identify patients that would probably meet time below range targets (t-CV <40% or wd-CV <34%).
Related Concept Videos
Hypoglycemia and Glucagon
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Oral Hypoglycemic Agents: Glinides
Diabetes Mellitus: Type 2 and Gestational