Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Automated detection of atrial fibrillation based on vocal features analysis
Gregory Golovchiner1, Michael Glikson2, Moshe Swissa3
1Department of Cardiology, Rabin Medical Center, Petah Tikva, Israel.
Introduction:
Early detection of atrial fibrillation (AF) is desirable but challenging due to the often-asymptomatic nature of AF. Known screening methods are limited and most of them depend of electrocardiography or other techniques with direct contact with the skin. Analysis of voice signals from natural speech has been reported for several applications in medicine. The study goal was to evaluate the usefulness of vocal features analysis for the detection of AF.
Methods:
This prospective study was performed in two medical centers. Patients with persistent AF admitted for cardioversion were enrolled. The patients pronounced the vowels "Ahh" and "Ohh" were recorded synchronously with an ECG tracing. An algorithm was developed to provide an "AF indicator" for detection of AF from the speech signal.
Results:
A total of 158 patients were recruited. The final analysis of "Ahh" and "Ohh" syllables was performed on 143 and 142 patients, respectively. The mean age was 71.4 ± 9.3 and 43% of patients were females. The developed AF indicator was reliable. Its numerical value decreased significantly in sinus rhythm (SR) after the cardioversion ("Ahh": from 13.98 ± 3.10 to 7.49 ± 1.58; "Ohh": from 11.39 ± 2.99 to 2.99 ± 1.61). The values at SR were significantly more homogenous compared to AF as indicated by a lower standard deviation. The area under the receiver operating characteristic curve was >0.98 and >0.89 ("Ahh" and "Ohh," respectively, p < .001). The AF indicator sensitivity is 95% with 82% specificity.
Conclusion:
This study is the first report to demonstrate feasibility and reliability of the identification of AF episodes using voice analysis with acceptable accuracy, within the identified limitations of our study methods. The developed AF indicator has higher accuracy using the "Ahh" syllable versus "Ohh."
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.