Characterization of odorous industrial plumes by coupling fast and slow mass spectrometry techniques for volatile
Wen-Tzu Liu1, Wei-Cheng Liao2, Stephen M Griffith3
1Center for Environmental Monitoring and Technology, National Central University, Taoyuan 320317, Taiwan.
Abstract:
This study aimed to develop a technique to chemically characterize odor issues in neighborhoods of designated industrial zones with pronounced emissions of volatile organic compounds (VOCs). Due to the elusive nature of odor plumes, speedy detection with sufficient sensitivity is required to capture the plumes. In this demonstration, proton-transfer-reaction mass spectrometry (PTR-MS) was used as the front-line detection tool in an industrial zone to guide sampling canisters for in-laboratory analysis of 106 VOCs by gas chromatography-mass spectrometry/flame ionization detector (GC-MS/FID). The fast but less accurate PTR-MS coupled with the slow but accurate GC-MS/FID method effectively eliminates the drawbacks of each instrument and fortifies the strength of both when combined. A 10-day PTR-MS field screening period was conducted to determine suitable trigger VOC species with exceedingly high mixing ratios that were likely the culprits of foul odors. Twenty canister samples were then collected, triggered by m/z 43, 61 (ethyl acetate, fragments, EA), m/z 73 (methyl ethyl ketone, MEK), or m/z 88 (morpholine) in all cases. Internal consistency was confirmed by the high correlation of critical species in the PTR-MS and trigger samples. Several long-lived halocarbons were exploited as the intrinsic internal reference for quality assurance. Oxygenated VOCs (OVOCs) accounted for 15%-75% of the total VOC mixing ratios in the triggered samples. However, EA and MEK, the most prominent OVOC species, did not appear to have common sources with morpholine, which presented with PTR-MS peaks incoherent with the other OVOCs. Nevertheless, these distinctive OVOC plumes were consistent with the multiple types of odor reported by the local residents. In contrast with the triggered sampling, random samples in the same industrial zone and roadside samples in a major metropolitan area were collected. The pronounced OVOC content in the triggered samples highlighted the advantage over random grab sampling to address odor issues.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Aromatic Compound Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrum
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Overview