Use of a Lightweight Portable Fluoroscopy Device for Obtaining Weightbearing Ankle Images
Haggai Schermann1, Soheil Ashkani-Esfahani2, John Zhao2
1Foot & Ankle Research and Innovation Laboratory (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA; Foot and Ankle Service, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA; Division of Orthopedic Surgery, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel.
Abstract:
Portable fluoroscopy devices provide point-of-care imaging in emergency and out-patient clinics. In this prospective study, we compared weightbearing images of syndesmosis obtained using a novel lightweight portable battery-powered fluoroscopy device with those obtained with a conventional radiography device. Eleven healthy participants underwent bilateral 3-view weightbearing imaging of both ankles using a radiography (X-ray group) device and a portable fluoroscopy system (LPF group). Anteroposterior, mortise, and lateral views were compared between the 2 techniques. Radiographic measurements were done by 2 observers. These measurements included talar tilt, tibiofibular clear space, tibiofibular overlap, plafond malleolar angle, medial distal tibial angle, medial clear space, lateral distal tibial angle, anterior and posterior tibiofibular distance were measured using the appropriate view. Data were compared between the 2 techniques; the interobserver agreement was calculated within each group. P < .05 was considered statistically significant. Comparing the 2 imaging modalities, there was no significant difference between the measurements in LPF and X-ray groups except plafond malleolar angle. The overall interobserver agreement was excellent between the 2 observers. There was no significant difference between the measures by the 2 observers and between the bilateral ankles. Fluoroscopy was associated with about 50% extra radiation exposure, although the absolute amount of radiation was not clinically significant. These results support the use of weightbearing images using portable fluoroscopy device as an alternative for the conventional radiography systems.
Related Concept Videos
Ankle Joint
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Ultrasonography
During an ultrasonography procedure, a handheld device called...