Related Experiment Video
Updated: Sep 8, 2025

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Early Titration of Oxygen During Mechanical Ventilation Reduces Hyperoxemia in a Pilot, Feasibility, Randomized
Sonal R Pannu1, Matthew Exline1, Brett Klamer2
1Division of Pulmonary, Critical Care & Sleep Medicine, Department of Internal Medicine, The Ohio State University, Columbus, OH.
Abstract:
Timely regulation of oxygen (Fio2) is essential to prevent hyperoxemia or episodic hypoxemia. Exposure to excessive Fio2 is often noted early after onset of mechanical ventilation. In this pilot study, we examined the feasibility, safety, and efficacy of a clinical trial to prioritize Fio2 titration with electronic alerts to respiratory therapists.
Study Design:
Open-labeled, randomized control pilot trial.
Setting:
Medical ICU.
Subjects:
Adults requiring mechanical ventilation.
Interventions:
Protocolized oxygen titration was initiated one hour after initiation of mechanical ventilation. When Spo2 exceeded 92% while on Fio2 ≥ 0.5, an electronic alert to respiratory therapists was triggered at 30-minute intervals. In the control arm, respiratory therapists titrated Fio2 by standard physician's orders.
Measurements And Main Results:
The primary end point was to determine if early Fio2 titration based on automated alerts was feasible in terms of reducing hyperoxemia. Secondary analyses included the number and frequency of alerts, mechanical ventilation duration, and ICU length of stay. Among 135 randomized patients, 72 were assigned to the intervention arm and 63 to the control arm. A total 877 alerts were sent. Exposure to hyperoxemia was significantly reduced in the intervention group by a median of 7.5 hours (13.7 [interquartile range (IQR), 2.9-31.1] vs 21.2 [IQR, 10.9-64.4]; p < 0.0004). Maximal Fio2 titration during the first quartile resulted in significant reduction in mechanical ventilation duration and ICU stay. Minor hypoxemic events (Spo2 < 88%) represented 12% of alerts, 9% were transient and responded to a single Fio2 increase, whereas 3% of alerts were associated with recurrent transient hypoxemia.
Conclusions:
Our pilot study indicates that early Fio2 titration driven by automated alerts is feasible in the ICU, as reflected by a statistically significant reduction of hyperoxemia exposure, limited consequential hypoxemia, and reduced ICU resource utilization. The encouraging results of this pilot study need to be validated in a larger ICU cohort.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Mechanical Ventilation I: Indication and Settings
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...