Related Experiment Video
Updated: Sep 8, 2025

Role of Diffusion MRI Tractography in Endoscopic Endonasal Skull Base Surgery
Published on: July 5, 2021
Optimization of scan parameters to reduce acquisition time for RESOLVE-based diffusion kurtosis imaging (DKI) in
Yaoyao He1, Hao Chen1, Huiting Zhang2
1Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China.
Objective:
To shorten acquisition time of readout segmentation of long variable echo trains (RESOLVE)-based diffusion kurtosis imaging (DKI) via Readout Partial Fourier (RPF) and b-value combinations.
Methods:
The RESOLVE-based DKI images of 38 patients with nasopharyngeal carcinoma (NPC) were prospectively enrolled. For RESOLVE-based DKI images with 5/8 RPF and without RPF, objective and subjective evaluations of image quality were performed. A total of nine groups with different b-value combinations were simulated, and the influence of different b-value combinations for RESOLVE-RPF-based DKI sequences was assessed using the intraclass correlation coefficient (ICC).
Results:
The mean values of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in DKI images without RPF were higher than those with 5/8 RPF (252.9 ± 77.7 vs 247.3 ± 85.5 and 5.8 ± 2.8 vs 5.4 ± 2.3, respectively), but not significantly (p = 0.460 and p = 0.180, respectively). In comparing the ICCs between nine groups of different b-value combinations in RESOLVE-RPF-based DKI, group (200, 800, 2000 s/mm2), group (200, 400, 800, 2000 s/mm2) and group (200, 800, 1500, 2000 s/mm2) were not significantly different (p > 0.001) and showed excellent agreement (0.81-1.00) with that of group (200, 400, 800, 1500, 2000 s/mm2). Using b-value optimization and RPF technology, the group with RPF (200, 400, 800, 2000 s/mm2) showed a 56% reduced scanning compared with the group without RPF (200, 400, 800, 1500, 2000 s/mm2; 3 min 46 s vs 8 min 31 s, respectively).
Conclusion:
DKI with RPF did not significantly affect image quality, but both RPF and different b-value combinations can affect the scanning time. The combination of RPF and b-value optimization can ensure the stability of DKI parameters and reduce the scanning time by 56%.
Advances In Knowledge:
This work is to optimize scan parameters, e.g. RPF and b-value combinations, to reduce acquisition time for RESOLVE-based DKI in NPC. To our knowledge, the effect of RESOLVE-RPF and b-value combinations on DKI has not been reported.
More Related Videos
09:59A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014