Related Experiment Video
Updated: Sep 8, 2025

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
A software-based approach for calculating spatially resolved radiation exposure for structural radiation protection
Stefan Schwan1, Arbia Khezami2, Janina Hohnholz1
1Institute of Neuroscience and Medicine-4, Forschungszentrum Jülich GmbH, Jülich, Germany.
Abstract:
The objective of the work described is the development of a software tool to provide the calculation routines for structural radiation protection from positron and gamma emitters, for example,18F. The calculation of the generated local annual dose in the vicinity of these radioactive sources supports the engineering of structural measures necessary to meet regulatory guidelines. In addition to accuracy and precision, a visual and intuitive presentation of the calculation results enables fast evaluation. Finally, the calculated results are presented in a contour plot for design, evaluation, and documentation purposes. A python program was used to provide the calculation routines for structural radiation protection. For simplicity, the radiating sources can be considered as point sources. The attenuation of structural elements can be specified or, in the case of lead, calculated by virtue of its thickness. The calculated attenuation for the lead shielding is always slightly underestimated, which leads to a marginally higher calculated local dose rate than would be physically present. With the conservatively determined value, the structural radiation protection can be optimised in accordance with the general rule of as low as reasonably achievable. The pointwise comparison between the software results and the standard procedure for calculating the dose of points in space leads to similar values. In comparison with the general approach of calculating single representative points in the radiation protection area, the visual and intuitive presentation of the results supports the design and documentation of the measures required for structural radiation protection. In the present version of the software, the local dose rate and local annual dose are overestimated by a maximum of 4.5% in the case of lead shields. The proposed software, termed RadSoft, was successfully used to develop the structural radiation protection of a controlled area for hybrid magnetic resonance - positron emission tomography imaging, with the focus herein being on the requirements for PET.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Absorption of Radiation

