Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
A Comparison Study Between CNN-Based Deformed Planning CT and CycleGAN-Based Synthetic CT Methods for Improving iCBCT
Bo Yang1, Yankui Chang2, Yongguang Liang1
1Department of Radiation Oncology, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
Synthetic CT (sCT) generation using CycleGAN and deformed planning CT (dpCT) using CNN both enhance Varian Halcyon cone-beam CT image quality. sCT showed superior accuracy when planning CT and iCBCT differences were significant.
Area of Science:
- Medical Imaging
- Artificial Intelligence in Radiology
- Cone-Beam CT (CBCT)
Background:
- Improving image quality in cone-beam CT (CBCT) is crucial for accurate radiation therapy planning.
- Varian Halcyon system's in-room CBCT (iCBCT) requires enhancement for optimal diagnostic and treatment verification purposes.
Purpose of the Study:
- To compare the effectiveness of two image quality improvement methods for Varian Halcyon iCBCT.
- To evaluate deformed planning CT (dpCT) via convolutional neural network (CNN) against synthetic CT (sCT) generation via CycleGAN.
Main Methods:
- Utilized 190 paired pelvic CT and iCBCT datasets for training and testing.
- Developed a 3D multi-stage registration network (MSnet) for dpCT and trained a 2D CycleGAN for sCT generation.
- Assessed registration and sCT accuracy using Dice Similarity Coefficient (DSC) on organs like bladder, spinal cord, and bone marrow.
Main Results:
- Both dpCT and sCT methods improved iCBCT image quality.
- sCT generation achieved higher accuracy (DSC 0.884 vs. 0.769 for bladder) compared to dpCT.
- sCT demonstrated significantly better performance when planning CT and iCBCT volume differences were substantial (DSC 0.859 vs. 0.596 for bladder).
Conclusions:
- Both registration and sCT generation are effective in enhancing iCBCT image quality.
- sCT generation offers superior accuracy, particularly in cases with significant anatomical variations between planning CT and iCBCT.
More Related Videos
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...