Lung vascular changes as biomarkers of severity in systemic sclerosis-associated interstitial lung disease
Cosimo Bruni1,2, Mariaelena Occhipinti3, Michael Pienn4
1Division of Rheumatology, Deptartment of Experimental and Clinical Medicine, Azienda Ospedaliero Universitaria Careggi, Firenze, Italy.
Objectives:
It has recently become possible to assess lung vascular and parenchymal changes quantitatively in thoracic CT images using automated software tools. We investigated the vessel parameters of patients with SSc, quantified by CT imaging, and correlated them with interstitial lung disease (ILD) features.
Methods:
SSc patients undergoing standard of care pulmonary function testing and CT evaluation were retrospectively evaluated. CT images were analysed for ILD patterns and total pulmonary vascular volume (PVV) extents with Imbio lung texture analysis. Vascular analysis (volumes, numbers and densities of vessels, separating arteries and veins) was performed with an in-house developed software. A threshold of 5% ILD extent was chosen to define the presence of ILD, and commonly used cut-offs of lung function were adopted.
Results:
A total of 79 patients [52 women, 40 ILD, mean age 56.2 (s.d. 14.2) years, total ILD extent 9.5 (10.7)%, PVV/lung volume % 2.8%] were enrolled. Vascular parameters for total and separated PVV significantly correlated with functional parameters and ILD pattern extents. SSc-associated ILD (SSc-ILD) patients presented with an increased number and volume of arterial vessels, in particular those between 2 and 4 mm of diameter, and with a higher density of arteries and veins of <6 mm in diameter. Considering radiological and functional criteria concomitantly, as well as the descriptive trends from the longitudinal evaluations, the normalized PVVs, vessel numbers and densities increased progressively with the increase/worsening of ILD extent and functional impairment.
Conclusion:
In SSc patients CT vessel parameters increase in parallel with ILD extent and functional impairment, and may represent a biomarker of SSc-ILD severity.
Related Concept Videos
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...