Percutaneous Image-Guided Biopsy for a Comprehensive Hybridization Capture-Based Next-Generation Sequencing in Primary Lung Cancer: Safety, Efficacy, and Predictors of Outcome
Related Experiment Video For Comprehensive hybridization capture-based next-generation sequencing
Updated: Sep 7, 2025

Author Spotlight: Advancements in Molecular Biomarker Testing for Non-Squamous Non-Small Cell Lung Cancer
Published on: September 8, 2023
Ahmed Elsakka1,2, Elena N Petre1, Fourat Ridouani1
1Interventional Radiology Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York.
Introduction:
To evaluate factors associated with successful comprehensive genomic sequencing of image-guided percutaneous needle biopsies in patients with lung cancer using a broad hybrid capture-based next-generation sequencing assay (CHCA).
Methods:
We conducted a single-institution retrospective review of image-guided percutaneous transthoracic needle biopsies from January 2018 to December 2019. Samples with confirmed diagnosis of primary lung cancer and for which CHCA had been attempted were identified. Pathologic, clinical data and results of the CHCA were reviewed. Covariates associated with CHCA success were tested for using Fisher's exact test or Wilcoxon ranked sum test. Logistic regression was used to identify factors independently associated with likelihood of CHCA success.
Results:
CHCA was requested for 479 samples and was successful for 433 (91%), with a median coverage depth of 659X. Factors independently associated with lower likelihood of CHCA success included small tumor size (OR = 0.26 [95% confidence interval (CI): 0.11-0.62, p = 0.002]), intraoperative inadequacy on cytologic assessment (OR = 0.18 [95% CI: 0.06-0.63, p = 0.005]), small caliber needles (≥20-gauge) (OR = 0.22 [95% CI: 0.10-0.45, p < 0.001]), and presence of lung parenchymal abnormalities (OR = 0.12 [95% CI: 0.05-0.25, p < 0.001]). Pneumothorax requiring chest tube insertion occurred in 6% of the procedures. No grade IV complications or procedure-related deaths were reported.
Conclusions:
Percutaneous image-guided transthoracic needle biopsy is safe and has 91% success rate for CHCA in primary lung cancer. Intraoperative inadequacy, small caliber needle, presence of parenchymal abnormalities, and small tumor size (≤1 cm) are independently associated with likelihood of failure.
More Related Videos
11:20Simple and Rapid Method to Obtain High-quality Tumor DNA from Clinical-pathological Specimens Using Touch Imprint Cytology
Published on: March 21, 2018
13:24Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016