Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure
Malini Joshi1, Praveen Dhakane2, Shilpushp J Bhosale3
1Department of Anaesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
Background:
Fluid boluses are used in hemodynamically unstable patients with presumed hypovolemia, to improve tissue perfusion, in the perioperative period. Now less invasive methods, such as pulse pressure variation (PPV) and stroke volume variation (SVV) are increasingly being used. We investigated correlation between carotid and brachial artery velocity time integral (VTI) and compared both with PPV and SVV.
Methods:
We recruited 27 patients undergoing supra-major abdominal surgeries. When indicated (hypotension or increased lactate), a fluid bolus was given after measuring carotid and brachial artery VTI, PPV, and SVV. The change in SV was noted and patients were categorized as responders if the SV increased by >15%. We performed Bland Altman Agreement and calculated best sensitivity and specificity for the parameters.
Results:
Patients were found to be fluid responders on 29 instances. The correlation between PPV, SVV, carotid and brachial artery VTI was poor and the limits of agreement between them were wide. The Area under Curve (AUC) for PPV was 0.69, for SVV was 0.63, while those of Carotid and Brachial artery VTI (TAP and flow) were (0.53 and 0.54 for carotid) and (0.51 and 0.56 for brachial) respectively.
Conclusion:
We found poor agreement and weak correlation between both VTi (TAP and flow) measured at carotid and brachial arteries, suggesting that the readings at brachial vessel cannot be used interchangeably with those at carotid artery. The PPV and SVV were better than these parameters for predicting fluid responsiveness; however, their predictive ability (AUROC), sensitivity and specificity were much lower than previously reported. Further studies in this area are therefore required (CTRI Reg No: CTRI/2017/08/009243).
How To Cite This Article:
Joshi M, Dhakane P, Bhosale SJ, Phulambrikar R, Kulkarni AP. Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness. Indian J Crit Care Med 2022;26(2):179-184.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: