Related Experiment Video
Updated: Sep 7, 2025

Nondestructive Monitoring of Degradable Scaffold-Based Tissue-Engineered Blood Vessel Development Using Optical Coherence Tomography
Published on: October 3, 2018
Detection of subtle cartilage and bone tissue degeneration in the equine joint using polarisation-sensitive optical
M Goodwin1, M Klufts2, J Workman3
1Department of Physics, The University of Auckland, Auckland 1010, New Zealand; The Dodd-Walls Centre for Photonic and Quantum Technologies, Auckland 1010, New Zealand; Department of Chemical and Materials Engineering, University of Auckland, Auckland 1010, New Zealand.
Objective:
To explore the ability of polarisation-sensitive optical coherence tomography (PS-OCT) to rapidly identify subtle signs of tissue degeneration in the equine joint.
Method:
Polarisation-sensitive optical coherence tomography (PS-OCT) images were systematically acquired in four locations along the medial and lateral condyles of the third metacarpal bone in five dissected equine specimens. Intensity and retardation PS-OCT images, and anomalies observed therein, were then compared and validated with high resolution images of the tissue sections obtained using Differential Interference contrast (DIC) optical light microscopy.
Results:
The PS-OCT system was capable of imaging the entire equine osteochondral unit, and allowed delineation of the three structurally differentiated zones of the joint, that is, the articular cartilage matrix, zone of calcified cartilage and underlying subchondral bone. Importantly, PS-OCT imaging was able to detect underlying matrix and bone changes not visible without dissection and/or microscopy.
Conclusion:
PS-OCT has substantial potential to detect, non-invasively, sub-surface microstructural changes that are known to be associated with the early stages of joint tissue degeneration.
More Related Videos
07:08Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
Published on: January 10, 2019
07:06Destabilization of the Medial Meniscus and Cartilage Scratch Murine Model of Accelerated Osteoarthritis
Published on: July 6, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Bone Formation by Endochondral Ossification