Comparison of Improved Unidirectional Dual Velocity-Encoding MRI Methods
Pamela Franco1,2,3,4, Liliana Ma5,6, Susanne Schnell7
1Biomedical Imaging Center, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
Background:
In phase-contrast (PC) MRI, several dual velocity encoding methods have been proposed to robustly increase velocity-to-noise ratio (VNR), including a standard dual-VENC (SDV), an optimal dual-VENC (ODV), and bi- and triconditional methods.
Purpose:
To develop a correction method for the ODV approach and to perform a comparison between methods.
Study Type:
Case-control study.
Population:
Twenty-six volunteers.
Field Strength/Sequence:
1.5 T phase-contrast MRI with VENCs of 50, 75, and 150 cm/second.
Assessment:
Since we acquired single-VENC protocols, we used the background phase from high-VENC (VENCH ) to reconstruct the low-VENC (VENCL ) phase. We implemented and compared the unwrapping methods for different noise levels and also developed a correction of the ODV method.
Statistical Tests:
Shapiro-Wilk's normality test, two-way analysis of variance with homogeneity of variances was performed using Levene's test, and the significance level was adjusted by Tukey's multiple post hoc analysis with Bonferroni (P < 0.05).
Results:
Statistical analysis revealed no extreme outliers, normally distributed residuals, and homogeneous variances. We found statistically significant interaction between noise levels and the unwrapping methods. This implies that the number of non-unwrapped pixels increased with the noise level. We found that for β = VENCL /VENCH = 1/2, unwrapping methods were more robust to noise. The post hoc test showed a significant difference between the ODV corrected and the other methods, offering the best results regarding the number of unwrapped pixels.
Data Conclusions:
All methods performed similarly without noise, but the ODV corrected method was more robust to noise at the price of a higher computational time.
Level Of Evidence:
4 TECHNICAL EFFICACY STAGE: 1.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...