Related Experiment Video
Updated: Sep 7, 2025

Tuning the Acidity of Pt/ CNTs Catalysts for Hydrodeoxygenation of Diphenyl Ether
Published on: August 17, 2019
Using sequential H2O2 addition to sustain 1,2-dichloroethane detoxification by a nanoscale zerovalent iron-induced
Song-Thao Le1, Atsada Israpanich1, Tanapon Phenrat1
1Research Unit for Integrated Natural Resources Remediation and Reclamation (IN3R), Department of Civil Engineering, Faculty of Engineering, Naresuan University, Phitsanulok, Thailand; Center of Excellence for Sustainability of Health, Environment and Industry (SHEI), Faculty of Engineering, Naresuan University, Phitsanulok, Thailand.
Abstract:
1,2-dichloroethane (1,2-DCA) is a chlorinated hydrocarbon used for polyvinyl chloride plastic production. As such, 1,2-DCA is a common persistent contaminant in saturated zones. While nanoscale zerovalent iron (NZVI) is considered an effective reductant for removing a wide range of chlorinated hydrocarbons, 1,2-DCA is resistant to reduction by NZVI as well as by modified forms of NZVI (e.g., sulfidated-NZVI). Hydroxyl radicals produced in Fenton's reaction can effectively degrade 1,2-DCA, but Fenton's reaction requires the acidification of saturated zones to achieve a groundwater pH of 3 to facilitate the catalytic reaction. To overcome this problem, this study has developed a sequential treatment process using an NZVI-induced Fenton-like reaction that can effectively degrade 1,2-DCA at an initially neutral pH range. The experiments were conducted using a high 1,2-DCA concentration (2000 mg/L) to evaluate the feasibility of using the treatment process at source zones. The process degraded 99% of 1,2-DCA with a pseudo-first-order rate constant of 0.49 h-1. Unlike the single-stage treatment process, the sequential treatment can control the used H2O2 concentration in the system, thus sustaining the reaction and resulting in more efficient 1,2-DCA degradation. To mimic subsurface conditions, batch experiments were conducted to remove 1,2-DCA sorbed in contaminated soil. The results show that 99% removal of 1,2-DCA was obtained within 16 h. Additionally, this study suggests that the NZVI can be used for at least three consecutive 1,2-DCA degradation cycles while maintaining high removal efficiency.
More Related Videos
10:52Multiscale Sampling of a Heterogeneous Water/Metal Catalyst Interface using Density Functional Theory and Force-Field Molecular Dynamics
Published on: April 12, 2019
06:39Author Spotlight: Design and Evaluation of Au-Electroplated Carbon Fiber Cloth Electrodes for Hydrogen Peroxide Fuel Cells
Published on: October 20, 2023
Related Concept Videos
Extraction: Advanced Methods
Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide
Oxidation of Alkenes: Anti Dihydroxylation with Peroxy Acids