Related Experiment Video
Updated: Sep 7, 2025

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Prepectoral breast reconstruction with complete anterior implant coverage using a single, large, square-shaped
Hyun Ki Hong1, Yun Hyun Kim1, Joon Seok Lee1
1Department of Plastic and Reconstructive Surgery, School of Medicine, Kyungpook National University, 130 Dongdeokro, Jung-gu, Daegu, 41944, Korea.
Background:
Several studies have discussed various methods of prepectoral direct-to-implant (DTI) breast reconstruction using an acellular dermal matrix (ADM) prosthesis to achieve full coverage. However, methods for anterior coverage have rarely been reported. In this study, prepectoral DTI breast reconstruction with complete anterior implant coverage was performed using a square piece of ADM. This study aimed to introduce our prepectoral DTI technique and determine its functional and cosmetic outcomes as well as compare them with those of existing subpectoral DTI techniques.
Methods:
This prospective comparative study focused on 29 patients (35 breasts) and 34 patients (35 breasts) who underwent breast reconstruction via subpectoral implant insertion (control group) and anterior coverage prepectoral implant insertion (anterior coverage group), respectively. Postoperative complications were noted, and breast symmetry was evaluated using the Vectra H2 three-dimensional scanner. The modified Kyungpook National University Hospital Breast-Q (KNUH Breast-Q) scale was used to assess the patient's subjective satisfaction with the reconstruction and postoperative quality of life.
Results:
No remarkable differences in terms of complications (seroma, skin necrosis, nipple-areola complex necrosis, hematoma, capsular contracture, and infection) were noted in both groups. Compared with controls, considerably better results were observed among those in the anterior coverage group in terms of the mean drain removal period. Furthermore, those in the anterior coverage group showed greater symmetry on three-dimensional scans than the controls; however, this was not statistically significant. Subjective satisfaction and postoperative quality of life measured using the KNUH Breast-Q scale were not significantly different between both groups.
Conclusions:
Considering its stability, faster recovery time, and cosmetic benefit, prepectoral breast reconstruction with anterior implant coverage using a single, large ADM is a good choice to perform breast reconstruction with implant insertion in patients who have undergone mastectomy.
Level Of Evidence:
II.