Association of Contrast-Enhanced Ultrasound-Derived Kidney Cortical Microvascular Perfusion with Kidney Function
Anand Srivastava1, Anush Sridharan2, Rachel W Walmer3
1Division of Nephrology and Hypertension, Center for Translational Metabolism and Health, Institute for Public Health and Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
Background:
Individuals with chronic kidney disease (CKD) have decreased kidney cortical microvascular perfusion, which may lead to worsening kidney function over time, but methods to quantify kidney cortical microvascular perfusion are not feasible to incorporate into clinical practice. Contrast-enhanced ultrasound (CEUS) may quantify kidney cortical microvascular perfusion, which requires further investigation in individuals across the spectrum of kidney function.
Methods:
We performed CEUS on a native kidney of 83 individuals across the spectrum of kidney function and calculated quantitative CEUS-derived kidney cortical microvascular perfusion biomarkers. Participants had a continuous infusion of the microbubble contrast agent (Definity) with a flash-replenishment sequence during their CEUS scan. Lower values of the microbubble velocity (β) and perfusion index (β×A) may represent lower kidney cortical microvascular perfusion. Multivariable linear regression models tested the associations of the microbubble velocity (β) and perfusion index (β×A) with estimated glomerular filtration rate (eGFR).
Results:
Thirty-eight individuals with CKD (mean age±SD 65.2±12.6 years, median [IQR] eGFR 31.5 [18.9-41.5] ml/min per 1.73 m2), 37 individuals with end stage kidney disease (ESKD; age 54.8±12.3 years), and eight healthy volunteers (age 44.1±15.0 years, eGFR 117 [106-120] ml/min per 1.73 m2) underwent CEUS without side effects. Individuals with ESKD had the lowest microbubble velocity (β) and perfusion index (β×A) compared with individuals with CKD and healthy volunteers. The microbubble velocity (β) and perfusion index (β×A) had moderate positive correlations with eGFR (β: rs=0.44, P<0.001; β×A: rs=0.50, P<0.001). After multivariable adjustment, microbubble velocity (β) and perfusion index (β×A) remained significantly associated with eGFR (change in natural log transformed eGFR per 1 unit increase in natural log transformed biomarker: β, 0.38 [95%, CI 0.17 to 0.59]; β×A, 0.79 [95% CI, 0.45 to 1.13]).
Conclusions:
CEUS-derived kidney cortical microvascular perfusion biomarkers are associated with eGFR. Future studies are needed to determine if CEUS-derived kidney cortical microvascular perfusion biomarkers have prognostic value.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...
Imaging Studies II: Ultrasonography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography