Impact of left ventricular outflow tract calcium on valve geometry in self-expanding transcatheter aortic-valve replacement
Related Experiment Video
Updated: Sep 7, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Giorgio A Medranda1, Toby Rogers1,2, Michael Fuery1
1Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia, USA.
Insights
Left ventricular outflow tract (LVOT) calcium can affect transcatheter heart valve (THV) geometry after transcatheter aortic valve replacement (TAVR). However, the Evolut PRO/PRO+ THV maintains circularity and function despite moderate/severe LVOT calcium.
Area of Science:
- Cardiovascular Imaging and Intervention
- Biomaterials and Medical Devices
Background:
- Left ventricular outflow tract (LVOT) calcification presents challenges for contemporary transcatheter heart valves (THVs).
- The degree and location of LVOT calcium can influence THV deployment, potentially altering flow dynamics and shear stress, which may accelerate THV degeneration.
Purpose of the Study:
- To evaluate transcatheter heart valve (THV) geometry in relation to left ventricular outflow tract (LVOT) calcium burden.
- To assess the impact of LVOT calcium on hemodynamics and outcomes following transcatheter aortic valve replacement (TAVR) with a self-expanding THV.
Main Methods:
- Analysis of 107 patients from the EPROMPT registry (CoreValve Evolut Pro Prospective Registry) who underwent TAVR with CoreValve Evolut PRO/PRO+ THVs.
- Computed tomography (CT) scans at 30 days post-TAVR were used to analyze THV geometry and its interaction with the aortic root.
- Patients were stratified based on the degree of LVOT calcium: none/mild versus moderate/severe.
Main Results:
- Thirty-day THV inflows showed less eccentricity in patients with none/mild LVOT calcium compared to moderate/severe LVOT calcium.
- THV circularity was maintained at the waist, leaflet tips, and outflow across both groups.
- Low rates of moderate or severe paravalvular leak and similar mean gradients were observed in both cohorts.
Conclusions:
- Despite potential inflow deformities associated with moderate/severe LVOT calcium, the Evolut PRO/PRO+ THV demonstrates adaptability to elliptical aortic annuli.
- The device maintains its circularity and functional integrity at the leaflet and outflow levels, even in the presence of significant LVOT calcification.
Objectives:
Evaluate transcatheter heart valve (THV) geometry according to left ventricular outflow tract (LVOT) calcium degree and its impact on hemodynamics and outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a contemporary self-expanding THV.
Background:
LVOT calcium remains challenging for contemporary THVs. LVOT calcium location and degree may affect THV deployment and impact flow patterns and shear stress, accelerating THV degeneration.
Methods:
EPROMPT (CoreValve Evolut Pro Prospective Registry; NCT03423459) is a prospective, investigator-initiated, multicenter registry of patients undergoing TAVR using CoreValve Evolut PRO/PRO + THVs. A total of 107 patients were enrolled in EPROMPT's computed tomography (CT) cohort between January 2018 and October 2021. These patients underwent follow-up CT scan 30 days post-TAVR. We analyzed THV geometry and its interaction with the aortic root following deployment using 30-day post-TAVR CT in patients with none/mild versus moderate/severe LVOT calcium.
Results:
Thirty-day THV inflows were less eccentric in the short axis in patients with none/mild versus moderate/severe LVOT calcium (1.16 ± 0.09 vs. 1.21 ± 0.12; p = 0.007). THV became more circular and was similar between both cohorts at the THV waist (1.08 ± 0.06 vs. 1.09 ± 0.11; p = 0.551), leaflet tips (1.03 ± 0.04 vs. 1.05 ± 0.09; p = 0.299), and THV outflow (1.04 ± 2.2 vs. 1.03 ± 2.7; p = 0.143). Thirty-day > mild paravalvular leak was low in both cohorts (1.5% vs. 2.4%; p = 0.724); mean gradients were similar (7.7 ± 3.6 vs. 7.7 ± 3.4 mmHg; p = 0.955).
Conclusions:
Despite inflow deformities observed in patients with moderate/severe LVOT calcium, Evolut PRO/PRO + conforms to elliptical aortic annuli, maintaining circularity and proper function at the leaflets and outflow, even in patients with moderate/severe LVOT calcium.